Technical Specifications

Power source

Technical aspect CenTIG 200 DC CenTIG 200 AC/DC
Current range TIG 5-200 A 5-200 A
Current range MMA 10-140 A 10-140 A
Mains voltage +10% / -40% 1x230 V 1x230 V
Mains current max. 18.9 A 18.9 A
Efficiency 86% 85%
Open circuit power 26 W 26 W
Frequency (AC) - 25-300 Hz
Duty cycle 40%/40° 200 A 200 A
Duty cycle 60%/40° 200 A 200 A
Duty cycle 100%/40° 200 A 200 A
Electrode dimension 1.0 - 3.2 mm
Display size 7" 7"
Main plug Schuko Schuko
Plug front
  • 1 x plug (+)
  • 1 x plug (-)
  • 1 x torch plug, 7 pole
  • 1 x quick coupling for shielding gas
  • 1 x plug (+)
  • 1 x plug (-)
  • 1 x torch plug, 7 pole
  • 1 x quick coupling for shielding gas
Plug back
  • 1 x CAN plug for water unit
  • 1 x mains connection to water cooling unit, 5 pole
  • 1 x USB A plug for software updates
  • 1 x gas connection
  • 1 x power button
  • 1 x CAN plug for water unit
  • 1 x mains connection to water cooling unit, 5 pole
  • 1 x USB A plug for software updates
  • 1 x gas connection
  • 1 x power button
Dimensions (H/W/L) 356 x 210 x 602 mm 356 x 210 x 602 mm
Dimensions incl. trolley (H/W/L) 1087 x 670 x 602 mm 1087 x 670 x 602 mm
Weight 13 kg 13.6 kg
Weight incl. trolley 38 kg 38.6 kg
Application class S/CE S/CE
Protection class IP 23S IP 23S
Operating temperature range -10 – +40 °C -10 – +40 °C
Standards
  • DS/EN IEC 60974-1
  • DS/EN IEC 60974-10, class A
  • DS/EN IEC 60974-3
  • DS/EN IEC 60974-1
  • DS/EN IEC 60974-10, class A
  • DS/EN IEC 60974-3

Cooling unit

Technical aspect CenCl 1300 230V cooling unit
Cooling efficiency (1l/min) 1300 W
Tank capacity 2.5 litre
Flow 1.9 l/min at 1.2 bar measured at 60°C
Pressure max 3 bar
Standards IEC60974-2. IEC60974-10 CL.A
Protection class IP 23S
Dimensions 342 x 210 x 562 mm
Weight incl. cooling liquid 15 kg

Did you not find what you were looking for?

Need a technical specification not found in the table above? Please reach out to us, and we'll provide you with the information you need.

Contact Us